TRIOCOAT™ PUR 2050
  • 2 hours to degree – 4 hours before overcoating
  • 2К
  • semi-gloss

TRIOCOAT™ PUR 2050

Two-component polyurethane primer-enamel containing anti-corrosion pigments, forming coatings from matte to glossy finish.
Find price
  • The coating has excellent weather and wear resistance 
  • Wide operating range – from -60°C to +120°C. 
  • Airless spraying / pneumatic spraying / manual application. 
  • Can be applied at low temperatures – down to -10°C.

TRIOCOAT PUR 2050 — Technical Data Sheet

Two-component polyurethane primer-enamel. Two-component polyurethane primer-enamel containing anti-corrosion pigments, forming semi-gloss coatings.

MATERIAL DESCRIPTION

Two-component polyurethane primer-enamel containing anti-corrosion pigments, forming semi-gloss coatings.

TYPE AND RECOMMENDED USE

Suitable for painting surfaces exposed to atmospheric and/or chemical attack: steel structures, locomotives and railcars, truck trailers, cranes, transport and road machinery, agricultural machinery, process equipment (conveyors, crushers, substations, etc.). Used as a standalone coating for galvanized and aluminium surfaces, carbon and stainless steel. The coating has excellent weather and wear resistance. Typical service of the coating — in moderate, moderately cold and cold climates, and atmospheric corrosivity up to C5, CX (GOST 34667.2 (ISO 12944-2)). May be used for operating temperatures from minus 60 to plus 120 °C.

PHYSICAL CHARACTERISTICS

Color:According to RAL catalogue. Volume solids:58±5 % Coating gloss, % (according to GOST 35094, at 45°):37–55 Theoretical spreading rate:0.086 l/m² at DFT 50 µm.

Coating thickness:

Dry film thickness (DFT) of one coat: (50–100) µm.

Maximum DFT is 150 µm. Recommended number of coats — 1–2.

Film thickness WFT, µm DFT, µm
Minimum8650
Recommended:10360
172100

Drying time:

Drying time at DFT 60 µm
Surface temperature 0 °C 5 °C 10 °C 15 °C 20 °C 25 °C 30 °C 35 °C
Drying to degree 3 according to GOST 19007 9 h 7 h 5 h 3 h 2 h 1.5 h 1 h 45 min
Drying to application of the next coat — TRIOCOAT PUR 2050 24 h 10 h 7 h 5 h 4 h 3.5 h 3 h 2 h

Drying time is determined by the actual DFT. The drying times given in this section are for guidance only. When assessing actual drying time, it is also necessary to take into account the presence of air flows and relative air humidity.

SURFACE PREPARATION

The material is applied to a prepared and dry surface with a temperature at least 3 °C above the dew point. The preparation process includes the following general operations: degreasing of the surface (if necessary, with water and/or solvents (R-4, R-646)); desalting of the surface (if necessary); dust removal of the surface to degree 2 with a particle size of not more than class 2 according to ISO 8502-3. Elimination of surface defects — to P3 according to ISO 8501-3.

The preparation process includes the following additional operations:

  • for carbon steel — surface cleaning to grade Sa 2.5 according to GOST R ISO 8501-1-2014 with a recommended roughness profile Rz (50–75) µm; during repair, local cleaning P St 3 is allowed;
  • for stainless steel, galvanized and aluminium surfaces — treatment with light abrasive blast cleaning using a mineral abrasive, or sanding with tools and means for mechanical surface cleaning with non-metallic contact surfaces (abrasive wheels and discs, impact tool with a flexible belt structure, etc.).

On hot-dip galvanized surfaces, it is recommended to additionally apply a thin coat (DFT = (20–30) µm) of primer-enamel diluted by (25–30) % before applying the main coat.

For aluminium and galvanized surfaces, washing with fresh water or solutions of special detergents under pressure, or using brushes with non-metallic bristles, is allowed.

APPLICATION

Material preparation:

The material is two-component and requires mixing the base and the hardener separately. Mixing ratio 9 : 1 (base : hardener) by volume, with thorough stirring to a homogeneous mass.

Pot life:3½ h at 15 °C; 2½ h at 20 °C; 1 h at 35 °C. Application method:Airless spraying / Pneumatic spraying / Manual application (brush, roller). Thinner:Thinner TRIOSOLV 0003 (if necessary), up to 10 % by volume. For more detailed information, contact O3-Coatings. Nozzle diameter (recommended):.011"–.015" Operating pressure (recommended):(150–200) bar. Equipment cleaning:Thinner TRIOSOLV 0003, xylene. Environmental parameters:Air temperature not lower than minus 10 °C; relative air humidity not higher than 85 %.

(In closed rooms, provide supply-and-exhaust ventilation in the appropriate volume for the period of application and drying.)

STORAGE

24 months from the date of manufacture. It is recommended to store in a dry dark place in sealed factory packaging at a temperature from 0 to plus 30 °C, avoiding direct exposure to UV rays and other heat sources.

NOTE

Small deviations of the numerical values of physical quantities are permissible.

TRANSPORT PACKAGING

Base — 20 l euro pail; Hardener — 3 l euro pail.

HEALTH AND SAFETY

Refer to the Safety Data Sheet for the material.

TRIOCOAT PUR 2050 — Application Manual

Two-component polyurethane primer-enamel. Product description: see Technical Data Sheet for TRIOCOAT PUR 2050.

CONTENTS

The instruction provides guidance on surface preparation; material preparation for application; the application process and equipment used; storage conditions; safety precautions; fire safety measures; environmental protection; first aid measures.

SURFACE PREPARATION

The material is applied to a prepared and dry surface with a temperature at least 3 °C above the dew point. The preparation process includes the following general operations: degreasing of the surface (if necessary, with water and/or solvents (R-4, R-646)); desalting of the surface (if necessary; the salt content on the metal surface is assessed according to ISO 8502-6, ISO 8502-9 and after a complete cycle of surface preparation must not exceed 50 mg/m² for carbon steel and 20 mg/m² for stainless steel); dust removal of the surface to degree 2 with a particle size of not more than class 2 according to ISO 8502-3. Elimination of surface defects — to P3 according to ISO 8501-3.

The preparation process includes the following additional operations:

  • for carbon steel — surface cleaning to grade Sa 2.5 according to GOST R ISO 8501-1-2014 with a recommended roughness profile Rz (50–75) µm; during repair, local cleaning P St 3 is allowed;
  • for stainless steel, galvanized and aluminium surfaces — treatment with light abrasive blast cleaning using non-metallic sharp-edged abrasives, for example, coarse mineral abrasive — olivine sand, slags (calcium silicates, aluminium, aluminium oxide, garnet sand), as well as stainless steel abrasives providing a surface roughness Rz of not less than 20 µm. After abrasive blasting treatment, peaks and valleys on the surface must form a continuous pattern, without smooth, unprofiled areas. In the case when traces of contamination are present after abrasive blasting treatment, they should be removed using a stainless steel wire brush, after which, if necessary, repeat the abrasive blasting to obtain the required surface profile — "Grit" (G) with a surface roughness Rz (20–40) µm in accordance with ISO 8503-5. For small surface areas, and also during repair, mechanical cleaning using tools and means for mechanical surface cleaning with non-metallic contact surfaces (abrasive wheels and discs, impact tool with a flexible belt structure, etc.) may be used.

On hot-dip galvanized surfaces, it is recommended to additionally apply a thin coat (DFT = (20–30) µm) of primer-enamel diluted by (25–30) % before applying the main coat.

For aluminium and galvanized surfaces, washing with fresh water or solutions of special detergents under pressure, or using brushes with non-metallic bristles, is allowed.

MATERIAL PREPARATION

The material is supplied in euro pails: base — 20 l, hardener — 3 l.

After opening the container, before application, the base and the hardener must be mixed separately. Mixing in a ratio of 9 : 1 (base : hardener) by volume, with thorough stirring to a homogeneous mass.

TRIOCOAT PUR 2050 is a two-component polyurethane primer-enamel containing anti-corrosion pigments, with volume solids 58±5 %, forming semi-gloss coatings with gloss (37–55) % at an angle of 45° and coating class up to I according to GOST 35094.

APPLICATION

Application method:Airless spraying / Pneumatic spraying / Manual application Thinner:Thinner TRIOSOLV 0003 (if necessary), up to 10 % by volume. For more detailed information, contact O3-Coatings. Nozzle diameter (recommended):.011"–.015" Operating pressure (recommended):(150–200) bar Equipment cleaning:Thinner TRIOSOLV 0003, xylene

Recommended application conditions

  • air temperature not lower than minus 10 °C;
  • relative air humidity not higher than 85 %;
  • temperature of the surface to be painted at least 3 °C above the dew point;
  • absence of direct atmospheric precipitation.
IMPORTANT: Work is prohibited if the above parameters do not meet the requirements.

Control parameters before shift

Before the start of each work shift and every 4 (four) hours, it is recommended to check and record the following parameters:

  • environmental conditions (air temperature, relative humidity);
  • dew point temperature;
  • surface temperature;
  • absence of moisture and oil contamination on the surface;
  • absence of dust on the surface.

Equipment preparation

Before applying the material, pass a solvent through the spray equipment to clean it from previously used paints and coatings. The solvent depends directly on the type of materials used earlier. Equipment cleaning is also recommended at the end of the work shift.

Dry film thickness (DFT) of one coat: (50–100) µm. Maximum DFT is 150 µm. Recommended number of coats — 1–2.

DRYING TIME

Table 1 — Drying time at DFT 60 µm

Parameter 0 °C 5 °C 10 °C 15 °C 20 °C 25 °C 30 °C 35 °C
Drying to degree 3 according to GOST 19007 9 h7 h5 h3 h2 h1.5 h1 h45 min
Drying to application of the next coat — TRIOCOAT PUR 2050 24 h10 h7 h5 h4 h3.5 h3 h2 h

Drying time is determined by the actual DFT. The drying times given in this section are for guidance only. When assessing actual drying time, it is also necessary to take into account the presence of air flows and relative air humidity.

WET FILM THICKNESS CONTROL

Wet film thickness is controlled with a "comb" gauge using the last tooth touching the paint. Above each tooth of the comb, its gap value in microns from the "base" teeth (from 0) is marked.

When performing measurements, the comb must be installed perpendicular to the plane of the painted surface. After each measurement, the surface of the comb in contact with the paint must be thoroughly wiped with a clean cloth.

The wet film thickness of the coating must be recorded.

QUALITY CONTROL OF THE FINISHED COATING

Quality control of the finished coating is performed according to the following characteristics:

  • appearance (no sags, cracking, peeling, etc.) — a uniform coating;
  • dry film thickness is determined by the 80–20 rule: 80 % of the measured thicknesses must be not less than the thickness specified in the specification (nominal thickness); 20 % of the measured thicknesses must be not less than 80 % of the nominal thickness.

To measure the dry film thickness of coatings, it is recommended to use thickness gauges with a measuring range from 0 to 1000 µm.

STORAGE

It is recommended to store TRIOCOAT PUR 2050 in a well-ventilated dry room at a temperature from 0 to plus 30 °C in sealed factory packaging, indoors, avoiding direct exposure to UV rays.

The guaranteed shelf life of the material TRIOCOAT PUR 2050 is 24 months subject to storage conditions. The material should be used within the shelf life recommended by the manufacturer. The decision on the use of material with an exceeded shelf life is taken by a commission.

SAFETY PRECAUTIONS

General provisions

During work, the requirements of GOST 12.3.002, GOST 12.3.005, GOST R 12.3.052 must be observed. Hazardous and harmful production factors must be eliminated or reduced to acceptable levels. When organizing and performing painting work, physiologically justified work and rest regimes should be provided.

Personnel requirements

Persons not younger than 18 years of age who have completed the following are allowed to perform anti-corrosion works:

  • occupational safety training — according to Decree of the Government of the Russian Federation No. 2464 of 24 December 2021, industrial sanitation, fire and electrical safety;
  • vocational training.

Officials, in accordance with the requirements of SNiP 12-03 and SNiP 12-04, are responsible for compliance with labour protection and industrial safety requirements during work.

Workers must know:

  • hazardous and harmful production factors, harmful substances in the composition of the materials used in the air of the working zone and the nature of their effect on the human body;
  • instructions on the procedure for performing work and maintaining the workplace;
  • instructions on labour protection, fire safety, industrial sanitation;
  • personal hygiene rules;
  • rules for the use of personal protective equipment (PPE);
  • rules for providing first aid.

Safety requirements for surface preparation and painting

All work related to the use of paints and coatings in rooms must be carried out with operating general supply-and-exhaust and local exhaust ventilation according to GOST 12.4.021. Ventilation must ensure that the content of harmful substances in the air of the working zone does not exceed the maximum permissible concentrations in accordance with the requirements of GOST 12.1.005, SanPiN 1.2.3685.

Workers engaged in surface degreasing, preparation and application of paints and coatings must be provided with the following PPE:

  • protective painting suits, disposable or reusable, with a zipper running along the length of the garment for ease of putting on and taking off, elastic bands at the wrists, ankles and waist, and a hood;
  • technical rubber gloves according to GOST 2001;
  • safety glasses according to GOST 12.4.253 (EN 166:2002), symbol 3, or equivalent with the same functional purpose;
  • filtering respirators with an insulating face piece in the form of a half-mask according to GOST 12.4.296 with a combined RPE filter providing simultaneous protection against gases, vapours and aerosols according to GOST 12.4.235 AZRZ (brown-white), AKhRZ or equivalent with the same functional purpose;
  • footwear made of leather, with a hard toe to avoid injury to the feet in case of falling heavy objects; the sole is protected by a metal plate.
IMPORTANT: Working without PPE is PROHIBITED!

Storage of organic solvents at the workplace is allowed in hermetically sealed containers in an amount not exceeding the two-shift norm.

When working with solvents, observe the following safety requirements: use respiratory and eye PPE; work with the ventilation system turned on, providing air exchange at the required rate.

During surface preparation, the sandblaster must work in special clothing made of dust-proof fabric and a helmet of the MIOT-49 type, and use PRB-5 respirators with forced air supply.

Rules for handling toxic substances

TRIOCOAT PUR 2050 is manufactured in accordance with TU 20.30.22-321-40141638-2025 and is recommended for painting surfaces exposed to atmospheric and/or chemical attack: steel structures, locomotives and railcars, truck trailers, cranes, transport and road machinery, agricultural machinery, process equipment (conveyors, crushers, substations, etc.). Used as a standalone coating for galvanized and aluminium surfaces, carbon and stainless steel.

The coating has excellent weather and wear resistance. Typical service of the coating — in moderate, moderately cold and cold climates, and atmospheric corrosivity up to C5, CX (GOST 34667.2 (ISO 12944-2)).

May be used for operating temperatures from minus 60 to plus 120 °C.

The container in which TRIOCOAT PUR 2050 is located must have a label with the exact name and designation of the material contained in it. The container must be intact and have a tightly closing lid.

In case of accidental spillage of material, cover the spill area with sawdust or sand, having previously protected the respiratory organs. Contaminated solvents, sawdust, sand, rags, cloths should be collected in buckets and removed to specially designated places in accordance with the requirements of GOST 30772, GOST R 52107.

Eating and smoking is allowed only in specially designated places.

FIRE SAFETY MEASURES

Fire safety measures during painting work must be carried out in accordance with the Technical Regulation on Fire Safety Requirements (No. 123-FZ of 22 July 2008) and other regulatory documents.

The paints and coatings used are classified as flammable materials; therefore, fire safety measures are taken at the workplace in accordance with the requirements of GOST 12.1.004 and Decree of the Government of the Russian Federation No. 1479 of 16.09.2020 "On Approval of the Fire Regime Rules in the Russian Federation".

IMPORTANT: The use of water to extinguish a fire is prohibited.

When performing surface preparation for painting and painting works, it is not allowed to:

  • smoke, light fires, or carry out welding works within a radius of 25 m from the work site, as well as along the entire vertical in this zone;
  • heat production rooms and protected objects with electrical appliances of standard design.

In the event of a fire, people should be evacuated from the danger zone, the fire service should be notified, paints and coatings should be removed from the work zone, and fire extinguishing should be started with the available means in strict accordance with the approved plan.

ENVIRONMENTAL PROTECTION

During painting work, solid and liquid wastes are generated.

Table 2 — Waste and disposal methods

Waste nameWaste disposal method
Solid waste: material container — euro pails Dispose of containers as household waste. Euro pails can be used for technical purposes after the material has dried on the inner walls.
Liquid waste: solvent/cleaner for flushing painting equipment; material residues Disposed of by the work manufacturer in accordance with GOST 30772, GOST R 52107.

FIRST AID MEASURES

General: if poisoning is suspected, seek medical help.

In case of inhalation: if the product is inhaled, move the victim to fresh air, ensure rest and seek medical help.

In case of contact with eyes: if the product gets into the eyes, rinse them with plenty of clean running water and seek medical help.

In case of contact with skin: if the product gets on the skin, remove contaminated clothing and wash the contact area thoroughly with soap and water. The use of solvents or thinners is prohibited.

In case of contact with food: if the product enters the body with food, ensure rest for the victim and immediately seek medical help.

IMPORTANT: Do not induce vomiting.

Any questions?
Please contact us.

By staying on the site, you agree to the processing of cookies and user data for the purpose of the site's operation.. More

Ok