TRIOCOAT™ RVS 9710. Standalone Coating
  • 8 ч до перекрытия
  • 2К

TRIOCOAT™ RVS 9710. Standalone Coating

Epoxy-phenolic two-component material
Find price
 • Universal internal coating for tanks and pipes. Suitable for crude oil, fresh and sea water, salt solutions at high temperatures: crude oil 104°C, fresh water 98°C, sea water 82°C, salt solutions 65°C.
 • Withstands live steam treatment.
 • Easy maintenance of coated equipment. Light tone facilitates visual inspection and cleaning.
 • High operating temperatures of coated equipment. The coating can be used as a primer under insulation (maximum temperature under insulation 150°C).
 • Ease of application. Extended recoating interval: up to 28 days.

TRIOCOAT RVS 9710 — Technical Data Sheet

Standalone coating. Two-component epoxy-phenolic (novolac) coating.

MATERIAL DESCRIPTION

Two-component epoxy-phenolic (novolac) coating.

COATING PURPOSE

Intended for anti-corrosion protection of internal surfaces of tanks and tank cars for storage of process water, saline solutions, mineral oil, crude oil, petroleum products; insulated pipelines and equipment made of carbon and stainless steel. Operating temperature in a dry environment is from minus 196 to plus 200 °C.

PHYSICAL CHARACTERISTICS

Color:Grey, red. Volume solids:73±3 % Theoretical spreading rate:0.137 l/m² at DFT 100 µm.

Coating thickness:

Recommended thicknesses of 1 coat of the coating

Film thickness WFT, µm DFT, µm
Minimum137100
Maximum342250

It is recommended to obtain the operational coating thickness in 2 or 3 coats.

Drying time and overcoating interval:

Drying time at DFT 150 µm

Surface temperature 5 °C 20 °C 30 °C 40 °C
Drying to degree 3 14 h 6 h 4 h 3 h
Drying to application of the next coat — minimum 20 h 8 h 6 h 5 h
maximum 1 month

Drying time and overcoating intervals are determined by the actual DFT and external conditions. The drying times given in this section are for guidance only. Accelerated drying at elevated temperature is possible: 0.5 h of holding the coating at plus (20±5) °C, then 1 h at 50 °C (degree 3). When assessing the actual drying time, it is also necessary to take into account the presence of air flows and relative air humidity. In case of exceeding the overcoating interval of the material, it is necessary to carry out a set of measures to ensure roughness and intercoat adhesion.

SURFACE PREPARATION

The material can be applied to prepared and dry surfaces of carbon and stainless steel, concrete, with a temperature at least 3 °C above the dew point. For carbon steel, the preparation process includes the following operations: elimination of surface defects to P2 according to ISO 8501-3; degreasing of the surface (if necessary; recommended solvent — R4); surface cleaning to grade Sa 2.5 according to GOST R ISO 8501-1-2014 with a recommended roughness profile of 50–75 µm and desalting of the surface (if necessary); dust removal of the surface to degree 2 with a particle size of not more than class 2 according to ISO 8502-3.

Instructions on surface preparation of stainless steel and concrete before painting are given in the Application Manual.

APPLICATION

Material preparation:

The material is two-component; before application, it requires mixing the base and the hardener separately, and mixing in the ratios: 8 : 1 (base : hardener) by volume, with thorough stirring to a homogeneous mass.

Pot life:2.5 h at plus 15 °C; 2 h at plus 20 °C. Application method:Airless spraying, manual application. Thinner:Thinner TRIOSOLV 0002 (if necessary), up to 10 % by volume for airless spraying. For more detailed information, contact O3-Coatings. Nozzle diameter (recommended):.015"–.019" Operating pressure (recommended):Not less than 200 bar. Equipment cleaning:Thinner TRIOSOLV 0002 (other solvents may be used in agreement with O3-Coatings). Environmental parameters:Air temperature not lower than plus 5 °C; relative air humidity not higher than 85 %.

(In closed rooms, provide supply-and-exhaust ventilation in the appropriate volume for the period of application and drying.)

STORAGE

12 months from the date of manufacture. It is recommended to store in a dry dark place in sealed factory packaging at a temperature from plus 5 to plus 30 °C, avoiding direct exposure to UV rays and other heat sources.

TRANSPORT PACKAGING

Supplied in kits in euro pails.

HEALTH AND SAFETY

Refer to the Safety Data Sheet for the material.

TRIOCOAT RVS 9710 — Application Manual

Standalone coating. Product description: see Technical Data Sheet for TRIOCOAT RVS 9710.

CONTENTS

The instruction provides guidance on surface preparation; material preparation for application; the application process and equipment used; storage conditions; safety precautions; fire safety measures; environmental protection; first aid measures.

SURFACE PREPARATION

The material is applied to a prepared and dry surface with a temperature at least 3 °C above the dew point. The preparation process, depending on the type of surface, includes the following operations:

1. Carbon steel

  • elimination of surface defects to P2 according to ISO 8501-3;
  • degreasing of the surface (if necessary);
  • surface cleaning to grade Sa 2.5 according to GOST R ISO 8501-1 with a recommended roughness profile of (50–75) µm;
  • desalting of the surface (if necessary);
  • dust removal of the surface to degree 2 with a particle size of not more than class 2 according to ISO 8502-3.

2. Stainless steel

Abrasive blast cleaning to grade Sa 1 (ISO 8501-1) — light cleaning using a non-metallic abrasive. When inspected without magnification, the surface must be free from visible presence of oil, grease, dirt, foreign particles.

3. Concrete

The surface must be cleaned of dirt, dust, oil contaminants, dry, strong, without cracks, chips, protruding reinforcement, shells, influxes. Defective areas must be repaired. The roughness class must meet the following requirements:

Distance between protrusions and depressions, mm Base length of size, mm Total area of shells and depressions per 1 m², %, at depth up to 2 mm
0.6–1.2100Up to 0.2

Surface moisture of concrete (at a depth of 20 mm) — not more than 4 % by weight. pH of the concrete surface — not less than 7.

MATERIAL PREPARATION

TRIOCOAT RVS 9710 is a two-component epoxy-phenolic (novolac) coating with volume solids 73±3 %; thinner TRIOSOLV 0002 is used (up to 10 % by volume).

The material is supplied in kits in euro pails.

After opening the container, before application, the base must be mixed separately. Mixing is carried out in a ratio of 8 : 1 (base : hardener) by volume; stir thoroughly to a homogeneous mass.

APPLICATION

Application method:Airless spraying, manual application Thinner:TRIOSOLV 0002 (if necessary), up to 10 % by volume for airless spraying. For more detailed information, contact O3-Coatings. Nozzle diameter (recommended):.015"–.019" Operating pressure (recommended):Not less than 200 bar Equipment cleaning:TRIOSOLV 0002 (other solvents may be used in agreement with O3-Coatings)

Recommended application conditions

  • air temperature not lower than plus 5 °C;
  • relative air humidity not higher than 85 %.

In closed rooms, provide supply-and-exhaust ventilation in the appropriate volume for the period of application and drying.

IMPORTANT: It is prohibited to carry out material application works if the above parameters do not meet the required values.

Control parameters before shift

Before the start of each work shift and every 4 (four) hours, it is recommended to check and record the following parameters:

  • environmental conditions (air temperature, relative humidity);
  • dew point temperature;
  • surface temperature;
  • absence of moisture and oil contamination on the prepared surface;
  • absence of dust on the prepared surface.

Equipment preparation

Before applying the material, pass a solvent through the spray equipment to clean it from previously used paints and coatings. The solvent depends directly on the type of materials used earlier. Equipment cleaning is also recommended at the end of the work shift.

Minimum thickness of one dry coat — 100 µm, maximum — 250 µm. Maximum permissible coat thickness — 500 µm. It is recommended to obtain the operational coating thickness in 2 or 3 coats. The material should be applied by airless spraying; application with a brush or roller is allowed in hard-to-reach places or on small surfaces.

DRYING TIME

Table 1 — Drying time at DFT 150 µm

Parameter 5 °C 20 °C 30 °C 40 °C
Drying to touch14 h6 h4 h3 h
Drying to application of the next coat — minimum20 h8 h6 h5 h
Maximum1 month

Drying time and overcoating intervals, including the maximum, are determined by the actual DFT and external conditions. The drying times given in this section are for guidance only. When assessing the actual drying time, it is also necessary to take into account the presence of air flows and relative air humidity.

In case of exceeding the overcoating interval of the material, it is necessary to carry out a set of measures to ensure roughness and intercoat adhesion.

WET FILM THICKNESS CONTROL

Wet film thickness is controlled with a "comb" gauge using the last tooth touching the paint. Above each tooth of the comb, its gap value in microns from the "base" teeth (from 0) is marked.

When performing measurements, the comb must be installed perpendicular to the plane of the painted surface. After each measurement, the surface of the comb in contact with the paint must be thoroughly wiped with a clean cloth.

The wet film thicknesses of the coating must be recorded.

QUALITY CONTROL OF THE FINISHED COATING

Quality control of the finished coating is performed according to the following characteristics:

  • appearance (no sags, cracking, peeling, etc.) — a uniform matte coating of grey or red color;
  • dry film thickness is determined by the 80–20 rule: 80 % of the measured individual thicknesses must be not less than the thickness specified in the specification (nominal thickness (NDFT)); 20 % of the measured individual thicknesses must be not less than 80 % of the NDFT; all measured individual thicknesses must be less than or equal to the established maximum individual dry film thickness (for a single-coat coating — 250 µm, for a two-coat coating — 500 µm, three-coat — 750 µm); the average value of all individual dry film thicknesses must be equal to or greater than the NDFT.

STORAGE

It is recommended to store the epoxy-phenolic coating TRIOCOAT RVS 9710 in a well-ventilated dry room at a temperature from plus 5 to plus 30 °C in sealed factory packaging, indoors, avoiding direct exposure to UV rays and other heat sources.

The shelf life of TRIOCOAT RVS 9710 is 12 months subject to storage conditions. The material should be used within the shelf life recommended by the manufacturer. The decision on the use of material with a shelf life of more than 12 months is taken by a commission.

SAFETY PRECAUTIONS

General provisions

During work, the requirements of GOST 12.3.002, GOST 12.3.005, GOST R 12.3.052 must be observed. Hazardous and harmful production factors must be eliminated or reduced to acceptable levels. When organizing and performing painting work, physiologically justified work and rest regimes should be provided.

Personnel requirements

Persons not younger than 18 years of age who have completed the following are allowed to perform anti-corrosion works:

  • occupational safety training — according to Decree of the Government of the Russian Federation No. 2464 of 24 December 2021, industrial sanitation, fire and electrical safety;
  • vocational training.

Officials, in accordance with the requirements of SNiP 12-03 and SNiP 12-04, are responsible for compliance with labour protection and industrial safety requirements during work.

Workers must know:

  • hazardous and harmful production factors, harmful substances in the composition of the materials used in the air of the working zone and the nature of their effect on the human body;
  • instructions on the procedure for performing work and maintaining the workplace;
  • instructions on labour protection, fire safety, industrial sanitation;
  • personal hygiene rules;
  • rules for the use of personal protective equipment (PPE);
  • rules for providing first aid.

Safety requirements for surface preparation and painting

Workers engaged in surface degreasing, preparation and application of paints and coatings must be provided with the following PPE:

  • protective painting suits, disposable or reusable, with a zipper running along the length of the garment for ease of putting on and taking off, elastic bands at the wrists, ankles and waist, and a hood;
  • technical rubber gloves according to GOST 20010;
  • safety glasses according to GOST 12.4.253 (EN 166:2002), symbol 3, or equivalent with the same functional purpose;
  • filtering respirators with an insulating face piece in the form of a half-mask according to GOST 12.4.296 with a combined RPE filter providing simultaneous protection against gases, vapours and aerosols according to GOST 12.4.235 AZRZ (brown-white), AKhRZ or equivalent with the same functional purpose;
  • footwear made of leather, with a hard toe to avoid injury to the feet in case of falling heavy objects; the sole is protected by a metal plate.
IMPORTANT: Working without PPE is PROHIBITED!

Storage of organic solvents at the workplace is allowed in hermetically sealed containers in an amount not exceeding the two-shift norm.

When working with solvents, observe the following safety requirements: use respiratory and eye PPE; work with the ventilation system turned on, providing air exchange at the required rate.

During surface preparation, the sandblaster must work in special clothing made of dust-proof fabric and a helmet of the MIOT-49 type, and use PRB-5 respirators with forced air supply.

Rules for handling toxic substances

The epoxy-phenolic coating TRIOCOAT RVS 9710 is manufactured in accordance with TU 20.30.12-301-40141638-2025 and is recommended for anti-corrosion protection of the internal surface of tanks and tank cars.

The container in which the epoxy-phenolic coating TRIOCOAT RVS 9710 is located must have a label with the exact name and designation of the material contained in it. The container must be intact and have a tightly closing lid.

In case of accidental spillage of paint and coating materials, cover the spill area with sawdust or sand, having previously protected the respiratory organs. Contaminated solvents, sawdust, sand, rags, cloths should be collected in buckets and removed to specially designated places in accordance with the requirements of GOST 30772, GOST 30773, GOST 30774, GOST R 52107.

Eating and smoking is allowed only in specially designated places.

FIRE SAFETY MEASURES

Fire safety measures during painting work must be carried out in accordance with the Technical Regulation on Fire Safety Requirements (No. 123-FZ of 22 July 2008) and other regulatory documents.

The paints and coatings used are classified as flammable materials; therefore, fire safety measures are taken at the workplace in accordance with the requirements of GOST 12.1.004 and Decree of the Government of the Russian Federation No. 1479 of 16.09.2020 "On Approval of the Fire Regime Rules in the Russian Federation".

IMPORTANT: The use of water to extinguish a fire is prohibited.

When performing surface preparation for painting and painting works, it is not allowed to:

  • smoke, light fires, or carry out welding works within a radius of 25 m from the work site, as well as along the entire vertical in this zone;
  • heat production rooms and protected objects with electrical appliances of standard design.

In the event of a fire, people should be evacuated from the danger zone, the fire service should be notified, paints and coatings should be removed from the work zone, and fire extinguishing should be started with the available means in strict accordance with the approved plan.

ENVIRONMENTAL PROTECTION

During painting work, solid and liquid wastes are generated.

Table 2 — Waste and disposal methods

Waste nameWaste disposal method
Solid waste: material container — euro pails Dispose of containers as household waste. Euro pails can be used for technical purposes after the material has dried on the inner walls.
Liquid waste: solvent/cleaner for flushing painting equipment; material residues Disposed of by the work manufacturer in accordance with GOST 30772, GOST 30773, GOST 30774, GOST R 52107.

FIRST AID MEASURES

General: if poisoning is suspected, seek medical help.

In case of inhalation: if the product is inhaled, move the victim to fresh air, ensure rest and seek medical help.

In case of contact with eyes: if the product gets into the eyes, rinse them with plenty of clean running water and seek medical help.

In case of contact with skin: if the product gets on the skin, remove contaminated clothing and wash the contact area thoroughly with soap and water. The use of solvents or thinners is prohibited.

In case of contact with food: if the product enters the body with food, ensure rest for the victim and immediately seek medical help.

IMPORTANT: Do not induce vomiting.