TRIOCOR™ RVS 9510. Standalone coating
  • Application temperature from +5°C
  • 2К

TRIOCOR™ RVS 9510. Standalone coating

A two-pack epoxy phenolic coating
Find price
  • For use as part of a 2 coat system for internal coating of storage tanks and vessels containing crude oil and refined products.
  • Crude oil 104°С
  • Fresh water 98°С, sea water 82°С
  • Salt solutions 65°С
  • Withstands steaming
  • Light color. Simplified and more thorough inspection.
  • Suitable for use at up to 180°C operating temperature (Dry Heat). Maximum temperature under insulation 150°C.
  • Extended overcoating period: maximum 28 days.

TRIOCOR RVS 9510 — Technical Data Sheet

Epoxy phenolic coating. Two-pack epoxy phenolic coating.

DESCRIPTION

A two-pack epoxy phenolic coating.

TDS 2413/62 — Revised: September 2024.

TYPE AND RECOMMENDED USE

For protection of the internal surface of tanks and cisterns for storage of industrial water, salt solutions, mineral oil, crude oil, petroleum products; isolated pipelines and equipment from carbon and stainless steel. Suitable for operating temperatures in a dry environment from minus 196 °C to plus 200 °C.

PHYSICAL CONSTANTS

Colour:Grey, red. Volume solids:73 ± 3 % Theoretical spreading rate:0.137 ltr/m² – at 100 microns DFT.

RECOMMENDED THICKNESS OF ONE COAT

Film thickness WFT, microns DFT, microns
Minimum137100
Maximum340250

It is recommended to obtain a thickness of 2 or 3 coats.

DRYING AND RECOATING TIMES

Drying times at 150 microns DFT

Surface temperature 5 °C 20 °C 30 °C 40 °C
Drying to degree 3 14 hours 6 hours 4 hours 3 hours
Recoating time (Minimum) 20 hours 8 hours 6 hours 5 hours
Recoating time (Maximum) 1 month 1 month 1 month 1 month

The drying time depends on the thickness. These drying times are given as a guide only. Factors such as air movement and humidity must also be considered.

If the maximum recoating interval is exceeded, roughening of the surface is necessary to ensure intercoat adhesion.

SURFACE PREPARATION

Apply only on a dry and clean surface from carbon, stainless steel, concrete with a temperature at least 3 °C above the dew point.

There are following the surface of carbon preparation stages: remedy imperfections to P2 ISO 8501-3; remove oil and grease (if necessary; recommended solvent – P4); blast clean to Sa 2½ GOST R ISO 8501-1-2014 with average surface profile in the range 50–75 microns; remove salt if necessary; the surface is dedusting to degree 2 with particle size do not exceed rating 2 of ISO 8502-3.

Preparation the surface of stainless, concrete are given in application manual.

APPLICATION DETAILS

Material preparation:

A two-component material. Mix the base and component separately before mixing. Mixing Ratio: 8 parts of Base to 1 part of Additive by volume with careful mixing of the mixture.

Pot life:

2½ hours – 15 °C; 2 hours – 20 °C.

Application method:

Airless spraying / Manual application.

Thinner:

Thinner TRIOSOLV 0002 (if necessary), up to 10 % by volume at airless spraying. For detailed information, contact «O3-Coatings».

Nozzle size (recommended):.015″ – .019″ Operating pressure (recommended):Not less than 200 bar. Cleaning of tools:TRIOSOLV 0002. (Can be to use other solvents in agreement with the company «O3-Coatings»). Application conditions:Should be applied at temperatures above plus 5 °C; Relative humidity: 85 % maximum. (In closed rooms it is necessary to provide supply-and-exhaust ventilation during application and drying to the extent necessary).

STORAGE

12 months from date of manufacture. Product should be stored in dry, dark space at temperatures between plus 5 °C to plus 30 °C in the original sealed packaging, avoiding direct exposure to UV-rays and other sources of heat.

PACKAGE

Supplied as a kit in separate containers.

HEALTH AND SAFETY

Refer to the Safety Data Sheet before use.

TRIOCOR RVS 9510 — Application Manual

Epoxy phenolic coating. Product description: see Technical Data Sheet for TRIOCOR RVS 9510.

CONTENTS

The Manual describes the surface preparation; the product preparation for the application; technical application process and equipment; storage conditions; occupational safety; fire precaution measures; environmental protection; first aid measures.

SURFACE PREPARATION

The material is applied to a prepared and dry metal surface with a temperature of at least 3 °C above the dew point.

The preparation process, depending on the type of surface, includes the following operations:

  1. Carbon steel: elimination of surface defects to P2 according to ISO 8501-3; degreasing the surface (if necessary); surface cleaning to the degree Sa 2½ in accordance with GOST R ISO 8501-1-2014 with a recommended roughness profile of 50–75 μm; desalination of the surface (if necessary); dust removal of the surface to a power of 2 with a particle size of not more than 2 classes according to ISO 8502-3.
  2. Stainless steel: abrasive blasting to the degree of Sa 1 (ISO 8501-1) – easy cleaning with using non-metallic abrasive. When viewed without magnification, the surface must be free from the visible presence of oil, grease, dirt, foreign particles.
  3. Concrete: the surface must be dry, durable and cleaned of dirt, dust, oil contamination. The surface should not have potholes, protruding fittings, shells, and swells. Defective places must be repaired. The roughness class must meet the following requirements:
    Distance between protrusions and depressions, mm Base size length, mm Total area of individual shells and recesses per 1 m², %, with a shell depth of up to 2 mm
    0.6–1.2 100 Up to 0.2

    The surface moisture content of concrete (at a depth of 20 mm) is not more than 4 % by weight.

    The pH of the concrete surface is at least 7.

PREPARATION FOR THE APPLICATION

TRIOCOR RVS 9510 – a two-pack epoxy phenolic coating with a dry residue of 73±3 %, used diluent TRIOSOLV 0002 up to 10 % by volume.

The material is supplied in sets in eurocontainers.

After opening the container, the base and hardener must be mixed separately before application. Mixing is performed at a ratio of 8 : 1 (base : hardener) by volume, stir well until homogenous mix.

APPLICATION

Application method:

Airless spraying / Manual application.

Thinner:

Thinner TRIOSOLV 0002 (if necessary), up to 10 % by volume with airless spraying. For more information, contact «O3-Coatings».

Nozzle size (recommended):.015″ – .019″ Operating pressure (recommended):Not less than 200 bar. Cleaning of tools:TRIOSOLV 0002. (Can be to use other solvents in agreement with the company «O3-Coatings»).

Recommended application conditions:

  1. air temperature is not lower than plus 5 °C;
  2. Relative air humidity is not higher than 85 %.

(In closed rooms it is necessary to provide supply-and-exhaust ventilation during application and drying to the extent necessary).

IMPORTANT: Work is prohibited if the above parameters do not match the required parameters.

Parameters control:

Before the beginning of each working shift and every 4 (four) hours, it is necessary to check the following parameters in the log of operational control:

  1. environmental conditions (air temperature, relative humidity);
  2. dew point temperature;
  3. Surface temperature;
  4. absence of moisture and oily impurities on the prepared surface;
  5. No dust on the prepared surface.

Before starting the application of the material, pass through the painting apparatus a solvent for cleaning the equipment from the previously used paintwork materials. The solvent directly depends on the type of materials used previously. It is recommended to clean the equipment also at the end of the work shift.

Minimum film thickness of one coat is 100 microns, maximum – 250 microns. It is recommended to obtain a thickness of 2 or 3 coats.

Apply the material by airless spraying; can be applied by brush or roller when applied in hard-to-reach areas or on small surfaces.

The drying time for a dry film thickness of TRIOCOR RVS 9510 150 μm is given in Table 1.

Table 1

Surface temperature 5 °C 20 °C 30 °C 40 °C
Drying to degree 3 14 h 6 h 4 h 3 h
Recoating time (Minimum) 20 h 8 h 6 h 5 h
Recoating time (Maximum) 1 month 1 month 1 month 1 month

The drying time is determined by the actual DFT and environmental conditions. The drying times given in this section are of a recommendation nature. When assessing the actual drying time, it is also necessary to take into account the presence of air currents and the relative humidity of the air.

If the maximum recoating interval is exceeded, roughening of the surface is necessary to ensure intercoat adhesion.

Wet layer thickness control:

Control of the thickness of the wet layer is carried out by the «comb» on the last tooth, touching the paint. Above each comb tooth is the size of its clearance in microns from the «basic» teeth (from 0).

When performing measurements, the comb must be installed perpendicular to the plane of the painted surface. After each measurement, the surface of the «comb», in contact with the paint, must be thoroughly wiped with a clean rag.

The thickness of the wet coating layer should be fixed.

Quality control of the finished coating:

Quality control of the finished coating is carried out according to the following characteristics:

  1. Appearance (there should be no streaks, cracking, peeling, etc.) – a homogeneous matte coating of white color;
  2. The dry film thickness is determined by rule 80–20:
    • 80 % of the measured thickness should be at least the thickness specified in the specification – (nominal thickness),
    • 20 % of the measured thickness should be at least 80 % of the nominal thickness.

    All measured individual thicknesses must be less than or equal to the established maximum of the individual thickness of the dry film (for a single-layer coating – 250 microns, for a two-layer coating – 500 microns, three-layer – 750 microns), the average value of all individual dry film thicknesses should be equal to or greater than nominal thickness.

IMPORTANT: Do not allow the next layer to be applied until the required coating thickness is reached.

To measure the thickness of the dry film of coatings, it is recommended to use thickness gauges with a measuring range from 0 to 5000 microns.

STORAGE CONDITIONS

Epoxy phenolic coating TRIOCOR RVS 9510 is recommended to store in a well ventilated dry room at a temperature from plus 5 to plus 30 °C in a hermetic factory package, in a confined space, to avoid direct exposure to UV rays and other sources of heat.

Shelf life TRIOCOR RVS 9510 is 12 months, subject to storage conditions. The material should be used within the manufacturer’s recommended shelf life. The decision on the use of a material with a shelf life of more than 12 months is taken by the commission.

OCCUPATIONAL SAFETY

General rules:

Works is carried out in accordance with the requirements of GOST 12.3.002, GOST 12.3.005, GOST R 12.3.052.

Occupational hazards and harmful should be eliminated or reduced to acceptable levels.

When organizing and carrying out painting works, a physiologically justified work-rest schedule should be provided.

Qualification requirements:

The application of the corrosion resistant coating can be conducted only by adults who are at least 18 years old that have undertaken:

  1. safety training in accordance with Resolution of the Russia Federation № 2464 of 24.12.2021, including occupational hygiene, fire and electrical safety;
  2. professional training.

The executive officers are held responsible for complying with the occupational and industrial safety requirements when conducting the application works, in accordance with the requirements of SNiP 12-03 and SNiP 12-04.

Workers must know about:

  • hazards, harmful occupational factors, harmful substances in the materials that affect the air in the workplace and how they can affect the human body;
  • application instructions and procedures, and requirements for the workplace maintenance;
  • workplace safety guidelines, fire safety, industrial health;
  • personal hygiene requirements;
  • requirements for using personal protective equipment (PPE);
  • first aid procedures.

Safety requirements for preparing and painting surfaces:

All work related to the use of paint and varnish materials in the premises should be carried out with working general exchange supply and exhaust and local exhaust ventilation according to GOST 12.4.021. Ventilation should ensure the content of harmful substances in the air of the working area not exceeding the maximum permissible concentrations in accordance with the requirements of GOST 12.1.005, SanPiN 1.2.3685.

Workers engaged in surface degreasing, preparation and application of paint and varnish materials should be provided with the following PPE:

  • protective suits for painting are disposable or reusable, having a zipper running along the length of the product for ease of putting on and removing, elastic bands on the wrists, ankles and waist, hood;
  • technical rubber gloves according to GOST 20010;
  • safety glasses according to GOST 12.4.253 (EN 166:2002), symbol 3 or similar with the same functional purpose;
  • filter respirators with an insulating front part in the form of a half mask according to GOST 12.4.296 with a combined SIZOD filter that provides protection against gases, vapors and aerosols at the same time according to GOST 12.4.235 A3P3 (brown-white), AHP3 or similar with the same functional purpose;
  • shoes made of leather, with a hard toe to avoid damage to the feet in the event of a heavy object falling; the sole is protected by a metal plate.
IMPORTANT: it is forbidden to work without a PPE!

Storage of organic solvents at the workplace is allowed in hermetically sealed containers in an amount of no more than a two-shift norm.

When working with solvents, observe the following safety requirements:

  • use PPE of respiratory organs and eyes;
  • work with the ventilation system switched on, ensuring the exchange of air of the required multiplicity.

When preparing the surface, a sandblaster worker must work in overalls made of dust–proof fabric and a MIOT 49 helmet, use PRB-5 respirators with forced air supply.

Requirements for handling toxic substances:

Epoxy-phenolic coating TRIOCOR RVS 9510 is manufactured in accordance with TU 20.30.12-110-40141638-2018 and is recommended for use for anticorrosion protection of the internal surface of tanks and cisterns.

Packaging containing the epoxy phenolic coating TRIOCOR RVS 9510, must have a label with the exact name and designation of the material contained in it. The packaging must be complete and have a tight-fitting lid.

In case of accidental spillage of paint and varnish materials, place the spill to be covered with sawdust or sand, beforehand protecting the respiratory system. Polluted solvents, sawdust, sand, rags and rags should be collected in buckets and removed to specially designated places in accordance with the requirements of GOST 30772, GOST 30773, GOST 30774, GOST R 52107.

Eating and smoking are allowed only in specially designated places.

FIRE PRECAUTION MEASURES

Fire precaution measures during coating application works must be carried out in accordance with the technical regulations related to fire safety requirements (July 22, 2008 №123-FZ) and other regulatory documents.

The coating materials are considered to be fire-hazardous, therefore, fire precaution measures in accordance with GOST 12.1.004 and Resolution of the Russia Federation № 1479 of 16.09.2020 «Rules of the Fire Fighting Regime in the Russian Federation» are carried out at the workplace.

IMPORTANT: Do not use water to extinguish fires.

When preparing the surface for coating application and when applying coating, it is prohibited:

  • to smoke, make a fire, conduct welding within a radius of 25 m from the workplace and along the vertical line below and above the area;
  • to heat the production facilities and protected objects with electrical appliances in a conventional way.

In the event of a fire, evacuate all people from the area, report the fire to the fire service, remove coating materials from the workplace, and proceed to extinguish the fire with the available means in strict accordance with the approved plan.

ENVIRONMENTAL PROTECTION

Coating application produces solid and liquid waste described in Table 2.

Table 2

Type of waste Method of waste management
Solid waste: Packaging of the product – Containers The packaging can be disposed of as domestic waste. Containers can be reused for technical purposes after the product remaining on the inner walls of the container has dried.
Liquid waste: Thinner / flushing liquid for cleaning the painting sprayer; Remains of the product The waste is disposed of by the product user in accordance with GOST 30772, GOST 30773, GOST 30774, GOST R 52107

FIRST AID MEASURES

General information:

In the case of a suspected poisoning, seek medical help.

After inhalation:

In the case of inhalation of the product, take the affected person to fresh air, keep them at rest and seek medical help.

After eye contact:

In the case of an eye contact with the product, flush the eyes with a lot of clean running water and seek medical help.

After skin contact:

In the case of skin contact, remove contaminated clothes and thoroughly clean the area of contact with soap and water. Do not use thinners or diluents.

After swallowing:

In case of swallowing, keep the affected person at rest and immediately seek medical help.

IMPORTANT: Do not induce vomiting.

Any questions?
Please contact us.

By staying on the site, you agree to the processing of cookies and user data for the purpose of the site's operation.. More

Ok