- Application: -10°С / +35°С
- 2К
TRIOCOR™ FINISH 5500. Acrylic polyurethane topcoat
- Available in a wide range of colors via RAL catalogue.
- Excellent gloss and color retention.
- Curing down to minus 10°С.
- No induction time.
- Indefinitely overcoatable by itself. That is important for logo’s application.
TRIOCOR FINISH 5500 — Technical Data Sheet
Acrylic polyurethane coating. Two-pack acrylic polyurethane topcoat.
DESCRIPTION
A two-pack acrylic polyurethane topcoat.
TDS 2513/23 — Revised: February 2025.
TYPE AND RECOMMENDED USE
As a topcoat to give protection of steel as part of an anti-corrosive coating system in severely corrosive environments up to C5 as defined in ISO 12944-2 including industrial and infrastructure facilities. It has high-performance decorative properties and very good gloss and colour retention under UV rays.
May be used at temperature up to plus 120 °C.
PHYSICAL CONSTANTS
TYPICAL THICKNESSES
| Film thickness | WFT, microns | DFT, microns |
|---|---|---|
| Recommended | 86 | 50 |
Film thicknesses: Normal range dry is 50–80 microns, maximum sag tolerance with overlap typically 100 microns.
DRYING TIMES
Drying times for 50 microns DFT
| Substrate temperature | 0 °C | 5 °C | 10 °C | 15 °C | 20 °C | 25 °C | 30 °C | 35 °C |
|---|---|---|---|---|---|---|---|---|
| To touch | 6 hours | 3 hours | 2 hours | 1 hour | 50 minutes | 45 minutes | 35 minutes | 30 minutes |
| To recoat: TRIOCOR FINISH 5500 | 24 hours | 16 hours | 12 hours | 8 hours | 7 hours | 6 hours | 5 hours | 4 hours |
Drying time is thickness dependent. These figures are given as a guide only. Factors such as air movement and humidity must also be considered.
SURFACE PREPARATION
This material should be applied on prior prepared and primed surface. Ensure surfaces to be coated are clean, dry and free from all surface contamination, with a temperature at least 3 °C above the dew point.
Typical surface preparation includes degreasing (if necessary), salt removing (if necessary) and dust removing from primed surface.
If the maximum overcoating interval of primed surface is exceeded, roughening of the surface is necessary to ensure intercoat adhesion.
APPLICATION DETAILS
Material preparation:
A two component material. Before mixing with the Additive stir the Base and the Additive separately. Mixing Ratio: 9 parts Base to 1 part Additive by volume, maintain stirring to have the wet paint as a homogeneous mixture.
Pot life:
3 ½ hours – 15 °C; 2 ½ hours – 20 °C; 1 hour – 35 °C.
Application method:
Airless spraying / Manual application.
Thinner:
TRIOSOLV 0003 (if necessary), up to 10 % by volume. Contact your O3-Coatings representative for additional data.
RECOMMENDED SYSTEMS
Primer: TRIOCOR MASTIC 4500. Contact your O3-Coatings representative for additional data.
STORAGE
For base: 24 months from date of manufacture, for additive: 12 months from date of manufacture. Store in dry, shaded conditions at temperature between 0 °C and plus 30 °C in hermetic original package away from UV rays and other sources of heat.
ADDITIONAL NOTE
Numerical values quoted for physical data may vary slightly from batch to batch.
PACKAGE
Base – 20L container; Additive – 3L container.
HEALTH AND SAFETY
Refer to the Safety Data Sheet before use.
TRIOCOR FINISH 5500 — Application Manual
Acrylic polyurethane coating. Product description: see Technical Data Sheet for TRIOCOR FINISH 5500.
CONTENTS
The Manual describe the surface preparation; the product preparation for the application; application details and equipment; storage conditions; occupational safety; fire precaution measures; environmental protection; first aid measures.
SURFACE PREPARATION
The product is applied to a prepared and dry surface with a temperature at least 3 °C above the dew point.
The process includes the following stages: degreasing of surface (if necessary); salt removing (if necessary); removing dust to dust quantity rating 2 for dust size class no higher than 2 in accordance with ISO 8502-3.
The surface should be cleaned with pressure 35 MPa by drinking water treatment, oil and grease should be removed with a thinner in accordance with GOST 9.402.
In case of the preceding coat’s surface damage, defects, chips, it is necessary to restore it in accordance with the coating manufacturer approved methods.
The product is applied to a clean dry primed surface after its preparation. The time interval between the surface preparation and the application of the product is determined by the environmental conditions and the characteristics of the materials used in accordance with the manufacturer’s recommendations.
If the surface is exposed to precipitation, make sure it is completely dry and repeat the surface preparation before applying the coating.
Avoid applying the product after exceeding the preceding layer overcoating interval recommended by the manufacturer. If the overcoating interval is exceeded, to ensure the adhesion with the preceding layer, roughen the surface by sweep blasting (light abrasive blast cleaning conducted at an angle of 30° to the surface and under half of the operating pressure) prior to applying the corrosion protection coating.
PREPARATION FOR THE APPLICATION
TRIOCOR FINISH 5500 is a two-pack acrylic polyurethane topcoat, with a volume solids of (58±5) %.
The product is supplied in containers: the base – 20 L, the hardener – 3 L.
After opening the container and before applying mix separately the base and the hardener. Mixing Ratio: 9 parts Base to 1 part Additive by volume, maintain stirring to have the wet paint as a homogeneous mixture.
APPLICATION
Application method:
Airless spraying / Manual application.
Thinner:
Thinner TRIOSOLV 0003 (if necessary), up to 10 % by volume. For more information, contact O3-Coatings.
Recommended application conditions:
- ambient air temperature above: minus 10 °C;
- relative humidity: 85 % maximum;
- surface temperature: at least 3 °C above the dew point;
- absence of direct contact with precipitation.
Parameters control:
Before the beginning of each working shift the following parameters must be monitored and recorded in the operations log:
- environmental conditions (ambient air temperature, relative humidity);
- dew point temperature;
- surface temperature;
- absence of moisture and oil contamination on the surface;
- absence of dust on the surface.
Before the application, use a thinner to clean the painting sprayer from preceding used materials. The choice of the thinner directly depends on the type of the preceding used materials. The equipment cleaning procedure must be also conducted at the end of each working shift.
The product is applied with an airless spray equipment; it can be applied with a brush for small areas and areas of difficult access.
When applied with an airless sprayer, minimum wet film thickness (WFT) with a single coat is 86 microns, which corresponds to dry film thickness (DFT) of 50 microns; maximum wet film thickness (WFT) with a single coat is 172 microns, which corresponds to dry film thickness (DFT) of 100 microns.
Table 1 — Drying time:
The drying times for TRIOCOR FINISH 5500 with the dry film thickness of 50 microns is shown in Table 1.
| Substrate temperature | 0 °C | 5 °C | 10 °C | 15 °C | 20 °C | 25 °C | 30 °C | 35 °C |
|---|---|---|---|---|---|---|---|---|
| To touch | 6 h | 3 h | 2 h | 1 h | 50 min | 45 min | 35 min | 30 min |
| To recoat: TRIOCOR FINISH 5500 | 24 h | 16 h | 12 h | 8 h | 7 h | 6 h | 5 h | 4 h |
Drying time is thickness dependent. These figures are given as a guide only. Factors such as air movement and humidity must also be considered.
Wet film thickness control:
The wet film thickness control is determined by the last notch of a coating thickness gauge that touched the film. Above each notch of coating thickness gauge the difference between its length and the length of the outside base notches (zero datum reference) is indicated.
When conducting measurements, the gauge should be set perpendicular to the coated surface. After each measurement, the parts of the gauge that were in contact with the coat must be carefully wiped with a clean cloth.
The wet film thickness of the coating must be recorded.
Quality control of the finished coating:
The quality control of the finished coating is done using the following characteristics:
- appearance (no sagging, cracking, peeling, etc.) – homogeneous coating;
- the dry film thickness is determined by the 80–20 rule:
- 80% of all measurements must not be below the thickness given in the specification (nominal thickness),
- 20 % of the measurements must be at least 80 % of the nominal thickness.
It is recommended to use coating thickness gauges with a measuring range from 0 to 5000 microns to measure the dry film thickness of the coating.
STORAGE CONDITIONS
Acrylic polyurethane topcoat TRIOCOR FINISH 5500 should be stored in a well-ventilated dry confined space at temperatures between 0 and plus 30 °C in hermetic original package away from UV rays.
The shelf life of TRIOCOR FINISH 5500 is 24 months for base and 12 months for additive if the recommended storage conditions are met. The product should be used within the recommended shelf life indicated by the manufacturer. The decision to use material that is over the shelf life is made by a committee.
OCCUPATIONAL SAFETY
General rules:
Works is carried out in accordance with the requirements of GOST 12.3.002, GOST 12.3.005, GOST R 12.3.052, Order of December 2, 2020 № 849n «On approval of the Rules for labor protection when performing painting works».
Occupational hazards and harmful should be eliminated or reduced to acceptable levels.
When organizing and carrying out painting works, a physiologically justified work-rest schedule should be provided.
Qualification requirements:
The application of the corrosion resistant coating can be conducted only by adults who are at least 18 years old that have undertaken:
- safety training in accordance with Resolution of December 24, 2021 No. 2464, including occupational hygiene, fire and electrical safety;
- professional training.
The executive officers have complete responsibility for compliance with the occupational and industrial safety requirements when conducting the application works, in accordance with the requirements of SNiP 12-03 and SNiP 12-04.
Workers must know about:
- hazards, harmful occupational factors, harmful substances in the materials that affect the air in the workplace and how they can affect the human body;
- application instructions and procedures, and requirements for the workplace maintenance;
- workplace safety guidelines, fire safety, industrial health;
- personal hygiene requirements;
- requirements for using personal protective equipment (PPE);
- first aid procedures.
Safety requirements for preparing and painting surfaces:
For any work related to the application of coatings in confined spaces, the general supply-exhaust ventilation and local exhaust ventilation are a prerequisite in accordance with GOST 12.4.021. The ventilation must ensure that the content of harmful substances in the air of the workplace does not exceed the maximum allowable concentrations, in accordance with the requirements of GOST 12.1.005, SanPiN 1.2.3685-21.
Workers engaged in degreasing the surface, preparing and applying paintwork materials should be provided with the following personal protective equipment:
- disposable or reusable protective suit for painting which has zipper runs for length of the product, elastics at wrists, ankles and at the waist, and hood;
- rubber technical gloves according to GOST 20010;
- safety glasses according to GOST 12.4.253 (EN 166:2002), symbol 3 or similar which has similar functional purpose;
- filter respirators which have isolating front part in form of half-mask according to GOST 12.4.296 equipped with combined filter, which provides the protection from gases, vapors and aerosols according to GOST 12.4.235 A3P3 (brown-white), AHP3 or similar which has similar functional purpose;
- shoes made from leather which has solid toes to avoid the injury of feet in case of the fall of a heavy object; sole must be protected with the metal plate.
Storage of organic thinners in the workplace is permitted in hermetically sealed containers in amount that don’t exceed two working shift doses.
When working with thinners observe the following safety requirements:
- use PPE for respiratory and eye protection;
- work with the activated ventilation system that ensures sufficient air exchange.
When preparing the surface, workers conducting sweep blasting must wear protective suits made from dust-proof material and helmets MIOT 49 type, use respirators PRB-5 with forced air supply.
Requirements for handling toxic substances:
Acrylic polyurethane topcoat TRIOCOR FINISH 5500 is produced in accordance with TU 20.30.22-038-40141638-2017 and it is recommended for use for corrosion protection in severely corrosive environments up to C5 as defined in ISO 12944-2 including industrial and infrastructure facilities.
The packaging of acrylic polyurethane topcoat TRIOCOR FINISH 5500 must have a label with the exact name and designation of the product that it contains. Containers must be whole and have a tight-fitting lid.
In a case of an accidental spill, the spill area must be covered with sawdust or sand after ensuring respiratory protection. Contaminated thinners, sawdust, sand, rags, cloths must be collected in pails and removed to specially designated areas in accordance with the requirements of GOST 30772, GOST R 52107.
Eating and smoking are only allowed in designated areas.
FIRE PRECAUTION MEASURES
Fire precaution measures during coating application works must be carried out in accordance with the technical regulations related to fire safety requirements (July 22, 2008 № 123-FZ) and other regulatory documents.
The coating materials are considered to be fire-hazardous, therefore, fire precaution measures in accordance with GOST 12.1.004 and Resolution of the Russia Federation № 1479 of 16.09.2020 «On approval of the Fire Safety Rules in the Russian Federation» are carried out at the workplace.
When preparing the surface and when applying coating, it is prohibited:
- to smoke, make a fire, conduct welding within a radius of 25 m from the workplace and along the vertical line below and above the area;
- to heat the production facilities and protected objects with electrical appliances in a conventional way.
In the event of a fire, evacuate all people from the area, report the fire to the fire service, remove coating materials from the workplace, and proceed to extinguish the fire with the available means in strict accordance with the approved plan.
ENVIRONMENTAL PROTECTION
Coating application produces solid and liquid waste described in Table 2.
Table 2
| Type of waste | Method of waste management |
|---|---|
| Solid waste: Packaging of the product – Containers | The packaging can be disposed of as domestic waste. Containers can be reused for technical purposes after the product remaining on the inner walls of the container has dried. |
| Liquid waste: 1. Thinner / flushing liquid for cleaning the painting sprayer 2. Remains of the product | The waste is disposed of by the product user in accordance with GOST 30772, GOST R 52107 |
FIRST AID MEASURES
General information:
In the case of a suspected poisoning, seek medical help.
After inhalation:
In the case of inhalation of the product, take the affected person to fresh air, keep them at rest and seek medical help.
After eye contact:
In the case of an eye contact with the product, flush the eyes with a lot of clean running water and seek medical help.
After skin contact:
In the case of skin contact, remove contaminated clothes and thoroughly clean the area of contact with soap and water. Do not use thinners or diluents.
After swallowing:
In case of swallowing, keep the affected person at rest and immediately seek medical help.
You may also be interested in
TRIOCOR™ ZINC 1700. Epoxy zinc rich primer
A two-pack epoxy zinc rich primer
Application temperature : -10°С / +35°С
Color : Gray
TRIOCOR™ MASTIC 4500 MIO. Modified epoxy primer
High-build modified epoxy MIO-pigment primer
Application temperature : -10°С / +35°С
Color : Gray
TRIOTEMP™ 400. High-temperature coating
Fast-drying two-component material consisting of an ethyl silicate-based binder and finely dispersed zinc powder.
Application temperature : +5°С
Color : Gray
Any questions?